OTe 25/220…240/700 PC

Product family benefits
  • Compact housing for mounting in very tight spaces
  • Compatible with the most common leading-edge and trailing-edge phase dimmers
Areas of application
  • Optional cable clamp E-style for independent mounting
  • Suitable for indoor installations
  • Suitable for indoor SELV installations
German innovation awards 2019 winner

Technical Data

Electrical data

Nominal input voltage

220…240 V

Mains frequency

50/60 Hz

Input voltage AC

198…264 V

Permitted voltage range

Total harmonic distortion

15 %

Power factor λ

0.90C…0.98

Full load at 230 V/Minimum load at 230 V

Efficiency in full-load

86 %

at 230 V, 50 Hz

Device power loss

3,9 W

Maximum

Inrush current

7 A

twidth = 100 µs (measured at 50 % Ipeak)

Max. ECG no. on circuit breaker 10 A (B)

41

Max. ECG no. on circuit breaker 16 A (B)

65

Max. ECG no. on circuit breaker 25 A (B)

-

Surge capability (L/N-Ground)

2 kV

Surge capability (L-N)

1 kV

Nominal output voltage

18…36 V

Maximum <48 V

U-OUT (working voltage)

50 V

Nominal output current

700 mA

±10%

Output current tolerance

±10 %

Output ripple current (100 Hz)

< 35 %

Typical

Output PSTLM

≤1

Output SVM

≤0.8

Nominal output power

25 W

Partial load 12.5…25 W

Maximum output power

25 W

Galvanic isolation primary/secondary

SELV

Current set

Fixed current

Dimensions & weight

Mounting hole spacing, length

-

Mounting hole spacing, width

-

Product weight

93.00 g

Cable cross-section, input side

0.75…1.5 mm²

Flexible

Cable cross-section, output side

0.5…1.5 mm²

Flexible

Wire preparation length, input side

8.0…9.0 mm

Wire preparation length, output side

8.0…9.0 mm

Length

95.0 mm

Height

30.0 mm

Width

53.0 mm

Colors & materials

Casing material

Plastic

Temperatures & operating conditions

Ambient temperature range

-20…+50 °C

Maximum temperature at tc test point

75 °C

Maximum at the Tc-point

Max.housing temperature in case of fault

110 °C

Temperature range at storage

-25…75 °C

Permitted rel. humidity during operation

5…85 %

Maximum 56 days/year at 85 %

Lifespan

ECG lifetime

50000 h

At Tcase = 70°C at Tc point / 10% failure rate

Capabilities

Dimmable

Yes

Dimming interface

Phase Cut

Leading edge

Dimming range

10…100 %

Dimming method

Amplitude Modulation

Overheating protection

Automatic reversible

Overload protection

Automatic reversible

Short-circuit protection

Automatic reversible

No-load proof

Yes

Intended for no-load operation

No

Max. cable length to lamp/LED module

2.0 m

Output wires must be routed as close as possible to each other

Suitable for fixtures with prot. class

I / II

Type of connection, output side

Push terminal

Suitable for through-wiring

No

Certificates & standards

Approval marks – approval

CE / ENEC 10 / VDE / CB

Standards

Acc. to EN 61347-1/Acc. to EN 61347-2-13/Acc. to EN 62384/Acc. to CISPR 15/Acc. to IEC 61000-3-2/Acc. to IEC 61000-3-3/Acc. to IEC 61347

Protection class

II

Type of protection

IP20

Logistical data

Commodity code

85044083900

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

05-05-2023

Primary Article Identifier

4052899105386

Candidate List Substance 1

Lead

CAS No. of substance 1

7439-92-1

Safe Use Instruction

The identification of the Candidate List substance is sufficient to allow safe use of the article.

Declaration No. in SCIP database

0324db9a-533b-47ff-ad8f-ecaea5912679

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4052899105386 UNV

Unpacked

1 95mm x 53mm x 30mm 93.00g 0.15dm³
4052899105393 VS

Shipping box

20 284mm x 207mm x 100mm 2138.00g 5.88dm³

Downloads

Accessories optional

Information about Family

Constant Current SELV drivers with leading- or trailing-edge dimming.

The compatibility with the most common leading-edge and trailing-edge phase dimmers and the possibility of 10…100% dimming pose some key benefits of this product. It can be used for SELV installations and the optional cable clamp enables independent installations.
Product family features
  • Dimmable via leading edge/trailing edge
  • Type of protection: IP20
Ecodesign regulation information:
Intended for use with LED modules.
The forward voltage of the LED light source shall be within the defined operating window of the control gear in all operating conditions including dimming if applicable.

Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Products

Sort by:
Product
Nominal output voltage
Nominal output current
Length
Width
Height
Data sheet
OTe 10/220…240/700 PC
7…14 V 700 mA 95.0 mm 53.0 mm 25.0 mm
OTe 13/220…240/350 PC
18…38 V 350 mA 95.0 mm 53.0 mm 25.0 mm
OTe 18/220…240/500 PC
18…36 V 500 mA 95.0 mm 53.0 mm 30.0 mm
OTe 18/220…240/350 PC
27…54 V 350 mA 95.0 mm 53.0 mm 30.0 mm
OTe 25/220…240/700 PC