PTo 70/220 240 3DIM
- Energy savings up to 30 % (compared to CCG operation) thanks to 3DIM (except PTo 35)
- High surge protection: up to 3 kV (L-N) / 4 kV (L/N-PE)
- Automatic safety shutdown of lamps in the event of a defect or at end of life (EoL)
- Excellent thermal behavior for very high limit temperatures tc and ta
- Suitable for luminaires of protection classes I and II
- Suitable for outdoor applications in luminaires with IP > 54
Safety advice
Ballast losses and lamp heat radiation can lead to heat accumulation in a completely closed case. Therefore it is necessary to ensure that the temperature at the measuring point t of the ECG does not exceed the maximum value.
Attention!
For safety reasons disconnect the device before replacing the lamp!
Technical Data
Electrical data
Lamp wattage
73 W
Maximum output power
73 W
Line current
0.35 A
Ignition voltage
4.5 kVp
Operating frequency
0.165 kHz
System wattage
80.00 W
Efficiency in full-load
91 %
Input voltage AC
198 264 V
Nominal voltage
220 240 V
Nominal input voltage (SD port)
220 240 V
Mains frequency
50 60 Hz
Power factor λ
0.95
Inrush current
35 A
Max. ECG no. on circuit breaker 10 A (B)
7
Max. ECG no. on circuit breaker 16 A (B)
13
Max. no. of ECGs on 16A MCB with EBN-OS
32
Protective conductor current
0.1 mA
U-OUT (working voltage)
250 V
Max. working voltage between LH and LL
250 V
Max. working voltage betw. LL/LH & earth
250 V
Max. capacitance of wire ECG/lamp
120 pF
Surge capability (L-N)
3 kV
Surge capability (L/N-Ground)
4 kV
Dimensions & weight
Length
133.0 mm
Width
77.0 mm
Height
48.0 mm
Mounting hole spacing, length
123.0 mm
Cable cross-section, input side
0.5 2.5 mm²
Cable cross-section, output side
0.5 2.5 mm²
Wire preparation length, input side
10 11 mm
Wire preparation length, output side
10 11 mm
Product weight
730.00 g
Colors & materials
Casing material
Plastic
Temperatures & operating conditions
Ambient temperature range
-25 +55 °C
Maximum temperature at tc test point
75 °C
Lifespan
ECG lifetime
60000 h
Additional product data
Required IP rating of luminaire
> 54
Design / version
ECG outdoor
Suitable for lamp power (1 lamp)
73 W
Capabilities
Dimming interface
DALI / StepDIM / AstroDIM
Dimming range
60 100 %
Max. cable length to lamp/LED module
1.5 m
Burn-in time prior to dimming operation
10 min
Overheating protection
Power reduction and switch off at T > 75 °C at the tc point
ECG reset time
> 0.5 s
Dimmable
Yes
Restriction on ignition time
20 min
Suitable for fixtures with prot. class
I / II
Lightning stroke protection
With connected equipotentiality-terminal 10 surges with 10 kV acc. to IEC 61000-4-5
Intended for no-load operation
No
Certificates & standards
Approval marks approval
ENEC 10 / VDE / VDE-EMC / EAC / C-Tick
Type of protection
IP20
EEI Energy Label
A2
Standards
Acc. to EN 61347-2-12/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN 61547/Acc. to EN 62386-101/Acc. to EN 62386-102/Acc. to EN 62386-103
Logistical data
Commodity code
85041080900
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
26-05-2023
Primary Article Identifier
4008321959355
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
bcf120de-714f-434e-a0eb-c29003ac7533
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4008321959355 |
UNV
| 1 | |||
4008321959362 |
VS
| 20 | 483mm x 285mm x 167mm | 15571.00g | 22.99dm³ |
Downloads
Information about Family
- 3DIM functionality (StepDIM/AstroDIM/DALI)
- Energy Efficiency Index EEI: A2
- Lightning protection: up to 10 kV
- Supply voltage: 220 240 V
- Line frequency: 50 60 Hz
- Line harmonics according to EN 61000-3-2
- Immunity according to EN 61547
- RI suppression: to EN 55015
- Safety: to EN 61347-2-12
- Luminous flux factor 1 compared with CCG operation
- Not suitable for DC operation
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
|
|
|
|
Data sheet | ||
---|---|---|---|---|---|---|---|---|
PTo 50/220
240 3DIM
|
48.0 mm | 220 240 V | 133.0 mm | 50 W | 4.5 kVp | |||
PTo 70/220
240 3DIM
|
48.0 mm | 220 240 V | 133.0 mm | 73 W | 4.5 kVp | |||
PTo 100/220
240 3DIM
|
42.5 mm | 220 240 V | 158.0 mm | 97 W | 4.5 kVp | |||
PTo 150/220
240 3DIM
|
42.5 mm | 220 240 V | 158.0 mm | 147 W | 4.5 kVp | |||
PTo 250/220
240 3DIM
|
60.0 mm | 220 240 V | 170.0 mm | 250 W | 4.5 kVp |